Multiplexer/Matrix Switch Module - High-Density PXI Switching Solutions

1. Standard PXle/CPCI/PCIe/PCI bus 3U board
2. Number of channels: 32-channel dual-pole double-throw switch outputs
3. Rated switching capacity: 30VDC@1A
4. Maximum switching voltage: 220VDC/250VAC
5. Maximum switching current: 1A
6. Maximum switching power: 30W, 62.5VA
7. Relay electrical life: ≥100,000 cycles (rated load: 30V/2A)
Meets NI product model requirements
OEM/ODM customization supported
Product Description

PXI3040L Multiplexer/Matrix Switch Module - High-Density PXI Switching Solutions

When you need reliable, flexible switching solutions for your test and measurement applications, our PXI3040L Multiplexer/Matrix Switch Module delivers exceptional performance and versatility. These professional-grade modules provide up to 80 channels of multiplexing and matrix switching capability, designed to meet the demanding requirements of automated test equipment, data acquisition systems, and high-channel-count signal routing applications. With 13 selectable topologies, configurable debounce timing, and compatibility with a range of terminal blocks, this switch module offers the adaptability you need for advanced test environments.

Description

The PXI3040L is a fully domesticated, PXI-based multiplexer/matrix switch module engineered for high-density signal routing in automated test environments. It supports up to 80 channels and offers 13 configurable switching topologies, ranging from 1-wire multiplexers to 8×10 matrix configurations, making it adaptable to diverse test scenarios. Built with high-reliability relays, it features configurable debounce time and built-in cycle counting for proactive maintenance. The module integrates seamlessly with SCB1291, SCB1292, and SCB1293 terminal blocks for quick, error-free wiring, and comes with intuitive driver software and example programs to streamline setup. With a compact 3U PXI form factor and robust performance, it is ideal for applications requiring flexible, high-channel-count switching.

Specifications

Parameter Value
Topology Options 1-wire 80×1 multiplexer, 1-wire 40×1 multiplexer, 1-wire 20×1 multiplexer, 2-wire 40×1 multiplexer, 2-wire 20×1 multiplexer, 1-wire 8×10 matrix, 2-wire 4×10 matrix, 1-wire 8×10 matrix, etc. (13 total)
Channel On-Resistance ≤30Ω (1-wire 80×1) / ≤20Ω (1-wire 8×10) / ≤nΩ (matrix modes, n = number of relays in path)
Channel Off-Resistance ≥100MΩ
Max Switching Current 0.5A
Max Switching Power 10W
Max Switching Voltage 60VDC, 30VAC (channel-to-channel, channel-to-ground)
Channel Isolation >55dB@200kHz, >40dB@1MHz
Relay Switching Time ≤1ms
Relay Lifespan ≥1×10⁶ cycles
Terminal Block Connector J30J-100ZKWPT7-J
Operating Temperature -10°C ~ +55°C
Storage Temperature -40°C ~ +70°C
Operating Humidity 10% ~ 90% RH, Non-Condensing
Storage Humidity 5% ~ 95% RH, Non-Condensing
Form Factor 3U PXI Single-Width Module

Applications

Automated Test Equipment (ATE): High-channel-count signal routing for functional testing of electronics

Data Acquisition Systems: Multiplexing sensor inputs for environmental and structural monitoring

Aerospace & Defense: Matrix switching for avionics and radar system validation

Laboratory Research: Flexible signal routing for prototype characterization and component testing

Industrial Automation: Multiplexing process control signals for factory test stations

Functionality

13 Configurable Topologies: Switch between multiplexer and matrix modes to match test requirements

High-Density Routing: Support for up to 80 channels in a single 3U PXI module

Relay Health Monitoring: Built-in cycle counting and configurable debounce time to optimize reliability

Simplified Wiring: Compatible with SCB1291/SCB1292/SCB1293 terminal blocks for quick connections

Intuitive Software Support: Includes driver libraries and example programs for easy integration with test frameworks

Broad Voltage/Current Handling: Supports 60VDC/30VAC and 0.5A switching for diverse load types

Key Features

Up to 80 channels in a compact 3U PXI form factor for space-efficient testing

13 flexible topologies to adapt to multiplexing and matrix switching needs

High-reliability relays with ≥1×10⁶ cycle lifespan and proactive maintenance tracking

Configurable debounce time to eliminate signal bounce and improve test accuracy

Plug-and-play terminal block compatibility for fast, error-free wiring

User-friendly driver software and example programs to accelerate deployment

Custom Design

At MXTD, we offer tailored solutions to meet your unique switching requirements:

Custom Topologies: Design of specialized multiplexer/matrix configurations beyond standard options

Extended Temperature Ranges: Modules rated for extreme -40°C to +85°C operating conditions

Enhanced Isolation: Higher voltage isolation for high-voltage test environments

Custom Connectors: Alternative terminal block and cable assemblies for legacy systems

Software Integration: Custom driver development for third-party test platforms

Customization Process

Why Choose MXTD?

Domestic Innovation: Fully localized design and manufacturing for reliable supply and fast support

Proven Reliability: ISO 9001-certified production processes ensure consistent performance

Technical Expertise: Years of experience in PXI module design and test system integration

Global Support: 24/7 technical assistance and rapid response to customer needs

Flexible Solutions: Fast lead times for both standard and custom-configured modules

Certifications and Certificates

Logistics and Transportation

FAQ

Q: How many channels does the PXI3040L support?

A: It supports up to 80 channels, with 13 configurable topologies for multiplexing and matrix switching.

Q: Can I use the PXI3040L with PXIe chassis?

A: Yes, it is compatible with both PXI and PXIe hybrid chassis.

Q: What terminal blocks are compatible with this module?

A: It works with SCB1291, SCB1292, and SCB1293 terminal blocks for simplified wiring.

Q: Does the module include software drivers?

A: Yes, it comes with intuitive driver software and example programs to streamline integration.

Q: What is the relay lifespan?

A: The relays are rated for ≥1×10⁶ cycles under resistive load conditions.

Contact us

Contact Us

Ready to enhance your test capabilities with our professional Multiplexer/Matrix Switch Module - High-Density PXI Switching Solutions? Our team is here to help you select the right configuration and provide technical support for your specific application.

Contact our sales team at manager02@mxtdinfo.com to discuss your requirements, request detailed specifications, or arrange product demonstrations. We look forward to helping you achieve your measurement and control objectives with our reliable switching technology.

Online Message

Our customers’ satisfaction speaks for our quality — contact us to experience the same reliable service.