The UT890C Digital Multimeter 6000 Count focuses on providing users with two core values: comprehensive functionality and thoughtful reminders:
Comprehensive Functions: Integrates multiple measurement functions such as voltage, current, resistance, capacitance, frequency, and temperature;
Thoughtful Reminders: Features a new automatic fuse-blowing alarm and overvoltage/overcurrent alarm prompts
Xi'an Mingxi Taida Information Technology Co., Ltd. brings over 12 years of industry expertise to deliver cutting-edge measurement and control solutions.With progressed computerization forms and strict quality control, we guarantee each item meets the most noteworthy guidelines for proficient applications.
The UT890C features both low-voltage and high-voltage frequency measurement modes:
| Mode | Voltage Range | Frequency Range | Application |
| Low-voltage Frequency Measurement | ≤30V | 10Hz ~ 10MHz | Electronic circuit signal measurement |
| High Voltage Frequency Measurement | 5V ~ 750V | 10Hz ~ 10kHz | Power Frequency Voltage Frequency Measurement |
True RMS vs. Ordinary Average Multimeter Comparison
| Applications | UT890C (True RMS) | Ordinary Average Multimeter |
| LED Lamp Voltage Measurement | ±1.5% accuracy | ±3% or higher deviation |
| Inverter Output | Accurate Reading | Possibly Severely Distorted |
| Switching Power Supply Measurement | Accurate and Reliable | Data Unreliable |
Advantages of 6000 counts vs. 2000 counts:
Fuse Blowing Alarm System- UT890C Digital Multimeter 6000 Count
The UT890C innovatively features an automatic fuse blowing alarm system:
| Large Capacitor Fast Charging Measurement | |||
| Maximum measurement range | 100mF | ||
| Response time | ≤12秒(100mF Capacitor) | ||
| Measuring range | 9.999nF ~ 99.99mF ( 9 gears) | ||
| Application | Repair of audio amplifiers, power boards, and motor starting capacitors | ||
| All-round overvoltage/overcurrent protection | |||
| High Voltage Misconnection Detection | 1000Vrms | Prevent damage caused by accidental connection to high voltage. | |
| Overcurrent Alarm | ≥20A | An alarm will sound if the current exceeds 20A | |
| Input Overload Protection | Full range coverage | The resistance tester will not burn out due to accidental connection of high voltage during resistance testing | |
| Security Level | CAT II 1000V / CAT III 600V | Meets International Safety Standards | |
UT890C Supporting:
✅True RMS, manual range,6000 count display
✅DC voltage (maximum 1000V),AC voltage (maximum 750V),Low-voltage frequency measurement
✅High voltage frequency measurement
✅DC current (maximum 20A),alternating current (maximum 20A),AC/DC mode memory
✅Resistance (maximum 60MΩ),capacitor (maximum 100mF),diode testing,transistor hFE test,On/off buzzer,temperature measurement
Comparison of Competing Products in The Same Price Range
| Item | UNI-T UT890C | Fluke 115 | Klein MM400 | AstroAI AM33D |
| Display Count | 6000 | 6000 | 6000 | 2000 |
| ACV Accuracy | ±(0.8%+3) | ±(1.0%+3) | ±(1.2%+5) | ±(1.5%+5) |
| DCV Accuracy | ±(0.5%+3) | ±(0.3%+2) | ±(0.5%+3) | ±(0.5%+3) |
| CAT Safety Level | CAT III 600V | CAT III 600V | CAT IV 600V | CAT II 600V |
| Battery Life | 500 hours | 400 hours | 300 hours | 200 hours |
| Capacitance Measurement | 100mF | 10mF | 100μF | 200μF |
| Frequency Measurement | 10MHz | 50kHz | 10MHz | 10MHz |
| Temperature Measurement | ✅ | ❌ | ✅ | ❌ |
| NCV Detection | ✅ | ❌ | ✅ | ✅ |
Applications:
We get it that standard arrangements do not continuously meet one of a kind prerequisites. Our experienced building group gives comprehensive OEM/ODM customization administrations. Whether you require adjusted recurrence ranges, specialized activating alternatives, or custom frame components, we work closely with you to create the idealize arrangement. Our adaptable plan approach guarantees your particular application needs are completely tended to whereas keeping up our quality standards.

Proven Encounter: Over 12 a long time of specialized skill in estimation and control frameworks development.
Expert Designing: Our gifted R&D group ceaselessly innovates to convey cutting-edge arrangements that keep you ahead of industry demands.
Quality Confirmation: Strict fabricating forms and comprehensive testing conventions guarantee dependable, steady performance.
Comprehensive Back: From starting meeting through progressing support, our committed group gives responsive specialized assistance.
Secure Conveyance: Collaborating with trusted coordinations suppliers guarantees secure, followed, and safety net provider shipment of your equipment.
Customer Center: We prioritize your victory with standard follow-ups, fast issue determination, and personalized benefit approaches.


Q:Why display error?
A: Instrument failure,need to stop using it and contact repair.
Q:Why abnormal buzzing sound?
A: Fuse Blows,need to replace Fuse.
Q:Why no response to the button?
A: Crash,need to remove the battery and reinstall it
Q: What could be causing a large deviation in the measured value?
A: Check if the test leads are making good contact.Confirm that the range selection is correct.Eliminate interference from the circuit being tested itself.Consider whether calibration is necessary.
Q: What to do if the capacitance setting cannot be zeroed?
A: Use the REL function to zero it.Check if the test leads are intact.Confirm that the jack is making good contact.
Q: What to do if NCV detection is insensitive?
A: Ensure the switch is in the NCV position.Move it close to the conductor being measured.Avoid environments with strong electromagnetic interference.Check the battery level.
✅Start with the highest range and gradually decrease it.
✅Ensure the test leads are correctly polarized during measurement.
✅Connect the red test lead to the positive terminal and the black test lead to the negative terminal.
✅Only applicable to sine and triangle waves.
✅Other waveforms are for reference only.
✅No polarity distinction required.
✅Power off before measurement to ensure the resistor being measured is not energized.
✅Zero-point correction is required for the 600Ω range.
✅For resistors less than 1MΩ, the REL function is recommended.

If you are looking for an affordable excellent choice. As the UT890C Digital Multimeter product line, the UT890C Digital Multimeter 6000 Count is highly entry-level to mid-range proffessional competitive in the digital multimeter market.It doesn't make you pay for features you don't need, yet it fully meets your requirements in terms of key measurement capabilities.
Email: manager03@mxtdinfo.com / manager02@mxtdinfo.com
Our customers’ satisfaction speaks for our quality — contact us to experience the same reliable service.